LWQ Series Gas Turbine Flometer Commercium
Home / Products / LWQ Gas Turbine Flowmeter / LWQ Series Gas Turbine Flometer
Get in Touch

Si auxilio egeas, placet liberum contactus nos

Jiangsu Vner Electronic Technology Co., Ltd.
Product Brochure
Jiangsu Vner Electronic Technology Co., Ltd. Jiangsu Vner Electronic Technology Co., Ltd.
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
  • LWQ Series Gas Turbine Flometer
Introductio producti
  • The LWQ Series Gas Turbine Flowmeter est summus accuratio gas fluunt metri secundum energiae principium. Gas advenientis primum stabilitur per diverticulum rectioris fluens, quod volutionem et turbulentiam minuit et profile fluxum conformat. Gas conditionatum tunc a multi- ensium turbine rotor agit; celeritas rotor proportionalis est velocitati gasi.

  • Rapina inductiva vel magnetica motum rotoris detegit et frequentiam generat signum fluxui volumini proportionalis. Composita cum temperatura et pressione integrata sensoriis et transmisso digitali, LWQ fluere potest vexillum vexillum (Nm³/h) per algorithms real-time recompensationem.

  • Cum fluxus inceptivus humilis, pressura parva damnum et iterabilitas optima, LWQ apta est ad vapores puros, siccos in metroing custodiae relatos, processum imperium, et applicationes administrationis industriae..

Praecipuae notae technicae
Item Descriptio
Principium mensuræ Gas Turbine - rotor celeritas proportionalis gasi velocitatis
metiri media Mundus, siccus vapores (v.g. gas naturale, nitrogen, aer, vapores inertes)
Sagaciter classes 1.0 %, 1.5% of rate (exemplum-dependens)
Repeatability 0,20% of rate
Nominal diametri DN25..DN400 (approx. 1"..16")
range mensuræ 1..15 m/s velocitas gas (size- et medium-dependens)
Turndown ratio Usque ad 1:20 (application- et magnitudine-dependens)
Processus hospites Flanged aut staminea
Connection signa DIN; ANSI/ASME; JIS
Medium temperatus range -30
Nominal pressura ratings PN16/PN25; ANSI 150/300; JIS 10K / 20K
Praesent / materiae corpus Carbon chalybe, SS304, SS316, aluminium cast.
Rotor / interna Aluminium mixtura, materia plastica corrosio-repugnantia (ABS)
Praesidium classis IP65 (vexillum)
CREPITUS praesidium Ex i / Ex d versions available
Potentia copia 24 V DC; 3.6 V constructum- in altilium (integrale genus)
Output annuit Pulsus 4-20 mA
Communicationis Modbus RS-485 (vexillum); T& P versiones compensantur computant Nm³/h
Testimonia ISO, PCEC (exemplum-dependens)
Effectus et Integratio
Categoria Specificationem / Bene Notae
Compensation Integrated temperatus & pressura (optio) Vera-vicis conversionem efficit ut vexillum volumen fluxus (Nm³/h)
Electronics Summus perficientur microprocessor VIII-segmentum linearization metri factor in melius accuracy
Ostendere LCD cum backlight (integralis versionibus) Real-time flow, totalized flow, pressure, temperatura (on T&P exempla)
Data repono EEPROM non-volatile memoria Multiplex logging modos ad historicam summam et clavem parametri
Virtus concept Humilis-potestas design Sustinet longam vitam altilium operationem seu externam 24 V DC supple
Outputs Pulsus 4-20 mA Compatible cum plurimis computatris, PLC et DCS systematibus
Communicationis Modbus RS-485 Integratio directa in SCADA, DCS et IIOT portarum
Pressura damnum Humilis resistentia interna Apta ad gas compressum et systemata naturalium gas distributio
Institutionem Foedus sensorem converter ecclesiam Simple institutionem in nova seu existentium gas lineae
Applicationes typicae
Industria / Sector Medium / Service Typical Usus
Naturalis gas distribution Natural gas Industriae / commercial gas exosculatio, consummatio vigilantia
Chemical & petrochemical Nitrogen, hydrogenii, processus gasorum Inerting, lodicula, processus gas feed et consummatio imperium
Oleum & gas Cibus gas, exardescere gas, instrumentum aeris Exuro suppeditat vigilantia, exardescit vigilantia, utilitas gas tracking
Virtus generation Boiler et turibulum gas Combustion control, efficientia vigilantia et industria statera
Industriae gasorum Oxygen, argon, CO₂, aer compressus Saturatio, distributio et planta magna usus magna (*arida & munda)
HVAC & utilitates Gas-accensus boilers, CHP unitates Gas consummatio mensurae ad aedificationem et plantam utilitates
Steel & metallurgy Fornax et converter gasorum Magna processus gasi influit in steelmaking et calor curatio
General faciens Systema pneumaticum, processus calentium Compressus aer et cibus gas usus per lineam vel per productionem unitatis
Exempla applicationis scaenarum
  • Industrialis Naturalis Gas Consummatio exosculatio et Energy Management

LWQ in DN50…DN150 lineae gasi naturales inauguratus, volumen reali temporis ac consummatio totalis mensurat. Cum temperatura et pressione recompensationem paravit, meter fluxum normatum praebet pro destinationi et efficientiae analysis.

  • NITROGENIUM Flow Cras in Inerting / Blanketing Systems

In chemicis piscinas reactorias vel reactorias, LWQ vestigia nitrogenii pro inertis adhibentur. Frequentia stabilis signum et Modbus output accurate imperium et longum tempus recordationem gasi usus patitur.

  • Compressi Aeris Cras in Multi-line pneumatica Networks

Turbina metra in principalibus vel ramo capitis compresso-aeris praebent fluxum notitiarum ad detectionem lacus et administrationem energiam. Humilis pressionis gutta designans regit additional onerationis in compressore systematis.

  • Flare Gas CURATIO in exacutione et petrochemical Plantis

LWQ in excandescentibus capitis vel lineis lateralibus inauguratus sustinet vigilantia voluminum gasorum excandescentium ad relationem internam staterae calculi, dummodo compositio gas et munditia apta sint.

  • Gas flow Control in Subcisione Calefactio Fornacis et Reactors

In fuel-gas pascitur fornacibus industrialibus vel reactoribus, LWQ iterabilem fluxum significationibus praebet ad systemata combustionis imperium, adiuvans conservare profiles temperaturas stabilis et processum qualitatis.

  • Comprobatio Gas flow permixtionem et Bottling stationes

In gasis industrialibus implendis vel miscendis skids, LWQ metra inter se amnis vel exitus coniunctos, operatores permittens ut puncta cognosceret et rationibus miscendis rectam poneret.

DE NOBIS

Ut Sina LWQ Series Gas Turbine Flometer Fabricae et LWQ Series Gas Turbine Flometer Officina, celebramur fabricandi professionalia et summae accurationis instrumenta industrialia. Peritia nostra in praebendo incomparabiles facultates mensurae fluxus, fulta per plus quam 12 annos experientiae solvendi applicationes complexas.
Instrumenta nostra mensurae fluxus praecisionis adhibentur a diverso genere utentium, a maioribus societatibus olei et gasi ad provisores photovoltaicos, fabricatores pharmaceuticos, et officia municipalia. Continue conferimus ad progressionem mensurae fluxus in industriis domesticis energiae et chemiae propter peritiam nostram in metiendis gasibus variabilis compositionis et mediis peculiaribus.

Wenzhou Hongfeng Electrical Alloy Co., Ltd.
Testimonium Honoris
  • VNER EAC TR CU
  • VNER EAC TR CU
  • VNER AC Series CE-EMC
  • VNER LWGY Series CE-EMC
  • VNER VE Series CE-EMC
  • VNER MA80T SIL2 Approbatio
  • SIL
  • VNER A Series Coriolis ECM 25 ATEX-B UQ44
News
Responsum Nuntii